Schneider (Xantrex) XW6048-230-50 Export Inverter

- Schneider (Previously Xantrex) XW6048-230-50 Export Hybrid Inverter Charger
The NEXT generation inverter/charger for renewable energy systems and backup power applications Xantrex brings the next generation of inverter/charger to market with the XW Hybrid Inverter/Charger, the heart of the XW System. Designed for off-grid and back-up power applications, the XW can operate with generators and renewable energy sources to provide reliable power every time. The XW Hybrid Inverter/Charger is a true sine wave inverter/charger that incorporates a DC to AC inverter, a battery charger, and an AC auto-transfer switch. It is the foundation for battery-based residential applications up to 18 kilowatts (kW), and commercial applications up to 36 kW in a three-phase configuration. Description Designed with consultations and input from industry experts, dealers, and installers, the XW sets a new standard for battery-based inverter/chargers. Integrating the best features available in the market, innovative new features by Xantrex and balance-of-systems components, the XW Hybrid Inverter/Charger’s design makes installation quicker and easier. The XW offers high efficiency and unprecedented surge capacity to maximize the owner’s return on investment. No other inverter/charger looks or performs like the XW. Features - True sine wave output
- Single phase (230 Vac) and three phase (400/230 Vac) configurations possible
- Dual AC inputs
- Several units can be connected in parallel
- XanBus – enabled network communication
- Unprecedented surge capacity
- Efficient, power factor corrected, high-current, multistage battery charging
Electrical Specifications Model: XW6048-230-50 Continuous output power: 6000 Watt Surge rating: 12,000 W Surge current: 53 A rms Waveform: True sine wave Peak efficiency: 95.4% Idle consumption - search mode:< 7 Watts AC connections: AC1 (grid), AC2 (generator) AC input voltage range (bypass/charge mode): 156 to 280 Vac (230 V nominal) AC input frequency range (bypass/charge mode):40 to 68 Hz (50 Hz nominal) AC output voltage: 230 Vac +/- 3% Maximum AC pass through current: 56 A AC output continuous current: 26.1 A AC output frequency: 50 Hz +/- 0.1 Hz Total harmonic distortion: < 5% at rated power Typical transfer time: 8 ms DC current at rated power: 131 A Utility-interactive: Disabled (default), AC voltage range 198 to 253 Vac, AC frequency range 49.1 to 50.9 Hz DC input voltage range: 44 to 64 V Continuous charge rate: 100 A Power factor corrected charging: PF (0.98) Mechanical Specifications Mounting: Wall mount, backplate included Inverter dimensions (H x W x D): 23 x 16 x 9” (580 x 410 x 230 mm) Inverter weight: 121.7 lb (55.2 kg) Supported battery types: Flooded (default), Gel, AGM, custom Battery bank size: 100 to 10000 Ah Battery temperature sensor: Included Non volatile memory: Yes Display panel: Status LEDs indicate AC In status, faults/warnings, equalize mode, On/Off and equalize button battery level. Three-character display indicates output power or charge current Multiple unit configurations: Single phase: up to 3 parallel units. Three-phase: 1 unit per phase System network: Xanbus™ Standard warranty: Five years Part number: 865-1035 Environmental Specifications Enclosure type: IP 20 (sensitive electric components sealed inside enclosure) Operational temperature range: -25 to 70 °C Accessories Remote display: Optional XW System Control Panel monitors and configures all devices connected to Xanbus™ Network Generator support: Optional XW Automatic Generator Start module connects to Xanbus™ Network. Automatically activates generator to recharge depleted battery bank or assist inverter with heavy loads Conduit Box: Optional XW Conduit Box encloses the bottom of the inverter and protects the cabling. Provides knockouts for 3/4” (20 mm), 1” (25 mm), 1.25” (32 mm), 2.25” (60 mm), and 2.5” (65 mm) conduit Solar Charge Controller: Optional XW Solar Charge Controller with maximum power point tracking delivers the maximum energy available from the PV array to the battery bank Regulatory Approval CE marked according to the following EU directives and standards: EMC Directive: EN61000-6-1, EN61000-6-3, EN61000-3-2, EN61000-3-3; Low Voltage Directive: EN50178 Specifications subject to change without notice. Optional Accessories - XW Conduit Box 865-1025
- XW Solar Charge Controller 865-1030
- XW System Control Panel 865-1050
- XW Automatic Generator Start 865-1060
Xantrex expects the system designer to use the XW Charge Controller with their inverters. Their sizing tools assume the XW Charge Controller. Most importantly, Xantrex handles the Ground Fault Protection (required by National Electric Code 2008 in all systems) in the charge controller. If you do not use the Xantrex XW Charge Controller then the GFP must be handled in a different way. Shipping dimensions: 28 x 22.25 x 10.5” (711 x 565 x 267 mm) Shipping weight: 169 lb (76.7 kg)
- No information available
-
Length: 28"
Width: 22.25"
Height: 10.5"
Weight: 169 lbs
-